Quick Answer
"Grade A" is a market label, not a legal certificate. BOMA International, whose class definitions are the best-known reference, describes office classes as relative to the local market and does not recommend publishing a class rating for individual buildings. In practice a Grade A building combines a strong location, efficient floor plates, reliable lifts and MEP systems, integrated building management, professional operation and evidence such as green certification. Test each claim with documents.
What matters most
No Egyptian authority certifies "Grade A"; treat it as a marketing description to verify.
Floor-plate efficiency, ceiling height and column layout decide how usable the space is.
Lift performance, HVAC zoning, power resilience and building systems separate premium from average.
Professional property management keeps a building Grade A after handover.
Green ratings such as LEED, EDGE or Egypt's Green Pyramid Rating System add verifiable evidence.
Stage 01
Grade A is relative, so define it with evidence
BOMA groups office space into Class A, B and C for comparison within a market, and its guidance notes that the classes are relative: a Class A building in one city may compete as Class B in another. That is why the label alone tells you little. A useful definition for a buyer or tenant is a list of measurable features, each backed by drawings, specifications or operating records.
Start with the market: what are the best buildings in the same district offering, and how does this one compare on access, systems, management and tenant mix?
Questions to resolve
- Which buildings is this one competing with?
- Which features can the seller document?
- Who will manage the building after handover?
Stage 02
Location, access and arrival
Location still comes first: proximity to transport, main roads, parking and the services employees use daily. In a planned district like the New Capital CBD, check how people actually arrive today and the published plans for transport links, separating what is operating from what is planned.
Arrival experience matters too: drop-off, lobby security, visitor management and the time from car park to desk. Ask for the traffic and parking strategy rather than relying on renderings.
Questions to resolve
- Current and planned transport access
- Parking ratio and visitor arrangements
- Lobby security and visitor flow
Stage 03
Floor plates, height and flexibility
Efficient floor plates have a compact core, few internal columns and enough depth for daylight to reach work areas. Floor-to-ceiling height, raised floors or other cable routes and a regular structural grid make fit-out easier and cheaper. Ask for the net-to-gross ratio using the contract's own area definitions.
Check flexibility: can the floor be split for several tenants, are there enough risers for data and services, and can the structure take heavier loads where needed?
Questions to resolve
- Net-to-gross efficiency
- Clear height and service routes
- Subdivision options and floor loading
Stage 04
Lifts, MEP and building systems
Lift capacity and waiting times shape daily life in a tower. Ask for the lift design study, not just the number of cars. For MEP, check HVAC zoning and out-of-hours cooling, fresh-air provision, electrical capacity per square metre, standby power and water resilience.
A building management system links HVAC, lighting, energy metering and alarms so the operator can run the building efficiently. Integration with fire, security and access control should be designed and tested, not assumed. AIG's Arabic guide explains what a BMS is and how it works.
Questions to resolve
- Lift traffic analysis
- HVAC zoning, fresh air and out-of-hours cooling
- Power capacity, standby supply and BMS integration
Stage 05
Management, sustainability and proof
A building can be well designed and still feel average if it is poorly run. Ask who manages it, the service levels, the maintenance plan and how service charges are budgeted and reported.
Green certification gives independent evidence of design and performance. LEED (USGBC), EDGE (IFC) and Egypt's Green Pyramid Rating System (HBRC) are used in the market. Ask whether a rating is targeted or achieved, and at which level.
Questions to resolve
- Named property manager and service levels
- Maintenance plan and reserve
- Certification status: targeted or achieved
Direct AIG Contact
Comparing premium office options?
Ask AIG for current floor plans and technical information so you can test AI Tower against the criteria that matter to your business.
First-party Context
Relevant AIG project: AI Tower, New Capital CBD

AIG presents AI Tower as an intelligent mixed-use tower in the New Capital CBD, with Honeywell named for building management, automation, security and safety systems. This guide does not award AI Tower a grade; use the criteria above and request current technical documents for the floor you are considering.
Practical checklist
Use these points to structure a meeting or tender enquiry. They are not a substitute for licensed local design, legal, health or engineering review.
Questions frequently raised by project teams
Is there an official Grade A certificate in Egypt?
No official national Grade A certificate exists. The term is a market description; verify it against measurable criteria and documents.
Is Grade A the same as green certified?
No. Many Grade A buildings pursue green certification, but a rating is a separate, independently assessed credential.
Does Grade A guarantee higher rents?
No. Rents depend on location, supply, demand and management. Quality can support demand, but nothing guarantees a return.
Sources & further reading